UPS battery maintenance is importance for power backup

Costa Power offers through the organization ALWAYS MAINTENANCE 10 – 120 kVA up to 8 units in parallel operation galvanic isolation at output line with the protect of latest technology of international brand you will benefit from a robust and easy to operate UPS meeting the relevant EMC and other international standards. It can be custom-designed for use in harsh industrial environments. With an expected lifetime of at least 20 years, the Protect 8 is a robust and cost-effective solution optimized for minimal operating costs.

Who would not appreciate a backup power supply? So, your uninterruptible power supply at the heart of it. Do you know that the many batteries that make up your UPS Battery  are each crucial to its functioning? One badly working battery can ruin your entire system. Especially in the places like data centre operations, this risk is highly unaffordable. Most of the time when you hear the UPS failed is because of the battery failure. There are different battery systems like the Vented Lead Acid (VLA), Nickel-Cadmium (NiCad), Valve- Regulated Lead Acid (VRLA). It is observed that batter is by far one of the most vulnerable parts of your UPS.

Therefore, the regular maintenance of it comes into play to make sure that you have a battery backup when you really need it. When we talk about why such a criticality occurs, then you must understand that the primary concern is its environment conditions. Unfavourable conditions adversely affect the battery life and may cause reduction of their life. Extreme environments affect their abilities to function, conduct and store properly. Did you know that it is estimated that an increase of 8-10 degree Celsius in the temperature causes the battery life to reduce into half.

Thus, it is important to refer to the specifications recommended by the manufacturers of the uninterruptable power supply to operate the battery in specified range of temperatures. Moreover, you must ensure that the batteries are charging correctly. For that you must pay attention to the float voltage and adjust it accordingly. There must be enough potential to charge the batteries. If you undercharge, it might reduce the life of the battery system. In some cases it may also be hazardous for your place.

While you are at it, make sure to perform yearly inspection. If you find any swelling or corrosion, beware of the premature failure of the battery. Do the visual inspection of the entire cabinet and rack. Look out for any leaking electrolyte which might cause interruptions in the circuit.

All in all, you must take care of the discussed factors like temperature, environment, leakage, float charge. Regular maintenance should result in longer life of the UPS battery system. Also, it is advisable to consult a trained person for inspection and maintenance purpose. If you are looking for UPS manufacturers in Mumbai then you can get in touch with us. We have clients from all over India and are in good position to provide you with the best services.