Costa Power Industries Pvt. Ltd. is a having global exposure as Manufacturers, Suppliers, Distributor and dealers of ups system , uninterruptible power supplier , ups power suppliers in mumbai , Emerson ups suppliers in mumbai , Emerson ups dealers , Emerson ups dealers in Mumbai . As headquarter is in economic capital of India, located in Mumbai and branches at PAN India. Costa Power Industries Pvt. Ltd. had started its operation in the field Since year successfully offering turnkey project services in the field of Electrical, Automation, Instrumentation, Energy Saving and Control with qualified & experience working team with solid technical background.
Costa Power Industries Pvt. Ltd. is ups suppliers , ups dealers chain of ups manufacturers , ups dealers in mumbai of global distributors such as emerson ups , best ups , single phase ups , digital ups , liebert emerson ups , emerson inverter , emerson best ups , emerson modular ups , three phase ups , emerson online ups , best emerson ups , emerson offline ups etc. Costa power provides battery backup system with customized solutions and ups preventive maintenance services , ups amc nationwide with a strong presence in the thane, Mumbai, Mumbai Suburbs, Maharashtra interior parts and in India.
Costa power design, build and service for Data centers, Communication networks, Commercial and industrial applications We support today with a portfolio of power, thermal and infrastructure management solutions by help of principal Company Vertiv. Costa Power offer unsurpassed global scale and broad expertise, built from our heritage as top ups dealers in Mumbai and providing Emerson ups distributors in Mumbai .
Costa believe in Innovation which enabling flexible and Fast deployment, turnkey project solutions and seamless service Intelligent systems for smart & holistic network Products, solutions, services and expertise for Emerson ups in Mumbai , and PAN India level as suppliers and distributors.
Costa have not only Expertise from design but commissioning derived from experience Innovative solutions that reduce costs, and speed deployment World-class services that drive uptime and deliver insights into performance Product, system and integrated solutions for Emerson ups dealers in thane and Emerson ups suppliers in Navi Mumbai with the exposure of across Maharashtra and in India.
Costa power is the best solution and service provide like ups amc vendor in Mumbai or ups amc service in Mumbai and in thane with PAN India residential solution to protect in even the most extreme conditions Solutions customized to meet specific needs and budget of customer who are looking for Emerson ups in Mumbai for their requirements.
As Costa power knows the importance of ups suppliers in Mumbai and value addition to clients requirements we always offers our mass-customized, standard solutions offer with ideal combination of best value and rapid delivery
CAPACITY | ITA 6 kVA | ITA 10 kVA | ITA 20 kVA |
---|---|---|---|
Input Parameters | |||
Rectier Type | IGBT Rectifier | ||
Rated Voltage | 220/380Vac single-phase three-wire/ three-phase four wire | 380Vac, three-phase four wire | |
Input voltage range | Single-phase 120Vac-276Vac /Three-phase 228Vac-478Vac | Single-phase 120Vac-288Vac Three-phase 228Vac-478Vac | Three-phase 228Vac-478Vac |
Input Freq Range | 45 Hz - 55 Hz | 45 Hz - 65 Hz | 40 Hz - 70 Hz |
Input Power Factor | 0.95 for Three Phase / >=0.99 for single Phase | >0.99 at Full Load | |
Battery | |||
Battery Type | Lead Acid Maintenance Free | ||
Charging Capability | 3 Hr of recharging of Standard Model | 6 Hr of recharging of Standard Model | Max Charging Power 4.5kW |
No of Battery | 16 Nos of Battery | 30 - 40 (Selected on Site) | |
Output Parameters | |||
Rated Power (kVA/kW) | 6kVA/6kW | 10kVA/10kW | 20kVA/20kW |
Rated Voltage | Single Phase 230/220 Vac | Three Phase 380/400/415 Vac and Single Phase 230/220 Vac | |
Voltage Precision | 3% | 1% | |
Frequency Precision | 0.25% | ||
Output Voltage THD | 3% for Linear Load and 5% for Non Linear Load |
2% for Linear Load and 5% for Non Linear Load |
|
Load Crest Factor | 3:1 Comply with IEC 62040-3 | ||
Step Load Performance | 100% | ||
Output Mode | Terminal Strip | ||
Overload Performance
(% of Rated Load) |
105%-125%; 1min | "105%-125%; 5 Mins, 125%-150%; 1Min | "105%-125%; 5 Mins, 125%-150%; 1Min |
System parameters and Standards | |||
System Efficiency @100% | Up to 91% | Up to 93% | Up to 94% |
Dimension (mm) | 430x625x85 | 435x640x85 | 435x750x130(3U |
Net Weight (kg) | 17.8 | 21.5 | 35 |
Output Ratings | |||
---|---|---|---|
Output Power | 6kVA/4.2kW | ||
Norminal Output Voltage | 230 AVC | ||
Output Voltage Regulation | +/-1% | ||
Output Voltage Distortion
-With 100% Non Linear Load |
3% | ||
Output Frequency Tolerance
Phase locked with Mains |
3% | ||
Norminal Output Frequency | 50 Hz | ||
Overload at 0.7 pf Load is
transferred to Bypass after pre-determined time |
150% for 5 seconds | ||
Input Ratings | |||
Norminal Input Power | 230 AVC | ||
Permissible Input Voltage
Variation at Full Load |
165 - 275 VAC | ||
Norminal Input Frequency | 50 Hz | ||
Permissible Input Frequency Variation | 45 Hz to 55 Hz | ||
Battery Details | |||
Norminal DC Bus Voltage | 192 VDC | ||
Number of Blocks of SMF
Batteries |
76 blocks of 12 v each | ||
Types of Batteries Supported | Sealed Maintenance (SMF) 165-275 VAC | ||
Recharge Time upto
100% Capacity |
12 hours | ||
Backup | 4 hours | ||
Physical Parameters | |||
Width X Depth X Height | 425x730x550 mm | ||
Weight | 95 kg | ||
Color | MoonLight Grey-Blue Structured |
Nominal Rating [kVA] | 80 | 120 | 160 | 200 | 250 | 300 | 400 |
---|---|---|---|---|---|---|---|
(0.8 pf)/kW | 64kW | 96kW | 128kW | 160kW | 200kW | 240kW | 320kW |
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p |
Environment | |||||||
Noise | 63dBA | 63dBA | 65dBA | 68dBA | 70dBA | 71dBA | 72dBA |
Temperature | Operating Temperature : 0 to 400C** ; Storage Temperature : -20 to 700C | ||||||
Humidity | 0 up to 95%, non-condensing. | ||||||
Altitude | up to 1000 m above mean sea level (MSL) without de-rating | ||||||
Physical Characteristics | |||||||
Depth [mm] | 875 | ||||||
Width [mm] | 900 | 1300 | 1250 | 1890 | 1250 | 1890 | 1250 | 1890 | 1400 | 2060 | 1640 | 2280 | 2460 | 2460 | ||||||
Height [mm] | 1900 | ||||||
Weight [kgs] | 750 | 1120 | 1000 | 1475 | 1200 | 1725 | 1350 | 2000 | 1650 | 2150 | 1850 | 2540 | 2400 | 3100 | ||||||
Ingress Protection Class | Degree of Protection : IP 20 ( IP : 31 On Request ) | ||||||
Color | RAL 7021 | ||||||
Input | |||||||
Voltage | 380/400/415V (+15/-15%) -3Ph - 3w | ||||||
Frequency | 50 or 60 Hz +/-10% | ||||||
I/P THDi Up to | 3% * | ||||||
Power Factor | Up to 0.99 * | ||||||
Bypass | |||||||
Voltage | 380/400/415V (+10/-10%) -3Ph – 4w | ||||||
Frequency | 50 or 60 Hz +/-5% | ||||||
Output | |||||||
Voltage | 380/400/415V - 3Ph - 4w | ||||||
Voltage Stability | |||||||
- Steady State | +/-1% | ||||||
- 100% Load Step | +/- 5% | ||||||
Power Factor | 0.8 lag to 0.9 lead w/o De-ration | ||||||
Frequency | 50 or 60Hz | ||||||
Frequency Stability | |||||||
- Synchronised with the bypass supplier | +/- 1 % | ||||||
- Auto-Synchronised | +/- 0.1% |
Model | 10KVA | 20KVA | |
---|---|---|---|
Rating | 10kVA (3in - 1out) | 20kVA (3in - 1out) | |
Input | Rated voltage | 400vac 3-phase,4 wire | 400Vac 3-Phase,4 wire |
Volatge Range | 176 -288VAC at 100% load; 100VAC - 288VAC at 50% load | ||
Rated Frequency | 50Hz/60Hz | ||
Frequency Range | 40Hz ~ 70Hz | ||
Power factor | ≥0.95 at full load | ||
Input phase reversal correction | Yes | No | |
Output | Rated power | 10KVA/10kW | 20KVA/20kW |
Voltage | 220/230/240VAC (single phase) | ||
Frequency synchronization range | Rated frequency±3Hz. Configurable range: ±0.5Hz ~ ±5Hz | ||
Rated Power Factor | Unity | ||
Crest Factor | 3 : 1 | ||
Voltage harmonic distortion | 2% (linear load) | ||
Voltage Regulation | 2% | ||
Dynamic response recovery time | 60ms | 40ms | |
Isolation transformer | Inbuilt at ups output | ||
Inverter Overload Capability the utility mode | At 25°C: 105% ~ 125%- 5min; 125% ~ 150%-1min; 150%- more than 200ms | ||
Inverter Overload Capability the battery mode | At 25°C :105% ~125%-60~ 30 s; >125%- more than 200ms | ||
Efficiency | ECO Mode | > 94% | > 94% |
Online mode (AC-AC) | > 91% | > 91% | |
Inverter Efficiency(DC-AC) | 88% | 88% | |
Battery | Type | Sealed, lead-acid,Tubular,LI-ION | |
No's of Batteries | 12(1), 16, 20; 16 by default | 24(1), 32, 40; 32 by default | |
Battery Fuse disconnector | Inbuilt | ||
Battery charging capacity | 8A | 13A |
Model | 1 kVA | 2 kVA | 3 kVA |
---|---|---|---|
OUTPUT PARAMETERS | |||
Capacity | 1kVA / 800W | 2kVA / 1600W | 3kVA / 2400W |
Power Factor | 0.8 | ||
Nominal Voltage | 220 / 230 / 240 Vac | ||
Voltage THD | 3% - Linear Load =6% - Non Linear load | 4% - Linear Load =7% - Non Linear load | 4% - Linear Load 7% - Non Linear load |
Frequency Regulation - Free Run
(Unsynchronised with bypass) |
+ / - 0.5 Hz | ||
Frequency Regulation (Synchronised with bypass) | 47.5 - 52.5 HZ / 57.5 - 62.5 HZ | ||
Creast Factor | 3:1 max. | ||
AC - AC Efficiency | 88% R-Load, 87% RCD - Load | ||
Transfer time - Mains to battery | 0 millisec | ||
Transfer time - Inverter to bypass -
Synchronisation mode |
4 msec | ||
INPUT PARAMETERS | |||
Configuration | 1 phase, L-N + PE | ||
Nominal Voltage | 230 Vac | ||
Voltage range | 160V to 300V at 100% Load, At 60% Load 110V to 300 Vac | ||
Frequency | 50 / 60 Hz | ||
Frequency range - Hz | 40 - 70 Hz | ||
Power Factor | >=0.95 | ||
BATTERY PARAMETERS | |||
Type | SMF | ||
No. of battery blocks (SB Model) | 3 X 7 Ah 6 X 7 Ah 6 X 9 Ah | ||
Battery Voltage (LB Model) | 36 VDC (3 Battery Blocks) | 96 VDC (8 Battery Blocks) | 96VDC (8 Battery Blocks) |
MODEL | GXT RT+ 1 kVA | GXT RT+ 2 kVA | GXT RT+ 3 kVA | ||
---|---|---|---|---|---|
Phase | 1 phase in / 1 phase out | ||||
CAPACITY | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | ||
INPUT | |||||
Nominal Voltage | 230 Vac | ||||
Voltage Range | Low Line Loss | 110 VAC ± 3% at 50% Load
176 VAC ± 3% at 100% Load |
|||
Low Line Comeback | 120 VAC ± 3% at 50% Load 186 VAC ± 3% at 100% Load | ||||
High Line Loss | 280 VAC ± 3% | ||||
High Line Comeback | 270 VAC ± 3% | ||||
Frequency Range | 40 Hz ~ 70 Hz | ||||
Power Factor | ≥ 0.99 @ 100% load | ||||
OUTPUT | |||||
Nominal Voltage | 208/220/230/240VAC | ||||
AC Voltage Regulation | ± 1% | ||||
Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | ≤ 3 % THD (Linear Load), ≤ 6 % THD (Non-linear Load) | ||||
Transfer Time | Bypass to Inverter (Line mode) | Zero | |||
Inverter to Bypass (Line mode) | 4 ms (Typical) | ||||
Waveform (Batt. Mode) | Pure Sinewave | ||||
EFFICIENCY on AC to AC mode@ 100% load. | 86% | 88% | 88% | ||
Inbuilt Isolation Transformer | No |
TECHNICAL SPECIFICATIONS | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ups Rating (kVA) | 100 | 120 | 160 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 |
Output active power at 35 °C*(kW) | 100 | 120 | 160 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 |
Output active power at 40 °C (kW) | 90 | 108 | 144 | 180 | 270 | 360 | 450 | 540 | 720 | 900 | 1080 |
INPUT | |||||||||||
Nominal mains input voltage / voltage range* (V) | 400 (200 to 460), 3Ph or 3Ph + N | ||||||||||
Nominal bypass input voltage / voltage range* (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | ||||||||||
Nominal frequency / frequency tolerance (Hz) | 50±10%(60 selectable) | ||||||||||
Input Power Factor | ≥ 0.99 | ||||||||||
Input current distortion (THDi) (%) | ≤3 | ||||||||||
OUTPUT | |||||||||||
Nominal output voltage (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | ||||||||||
Nominal output frequency (Hz) | 50 (60 selectable) | ||||||||||
Output voltage stability by load variation 0-100% (%) | ±1 Complies with IEC/EN 62040-3, Class 1 | ||||||||||
Output frequency stability | ±2 (2, 3, 4, 5 selectable) | ||||||||||
Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | ||||||||||
Short circuit current for 200 ms | 2.2 In | ||||||||||
Load crest factor handled without derating the ups (Ipk/Irms) | 3:1 | ||||||||||
Compatibility with loads | Any power factor (leading or lagging) up to 1 | ||||||||||
DIMENSION AND WEIGHT | |||||||||||
Height (mm) | 1950 | ||||||||||
Width (mm) | 500 | 750 | 1000 | 1250 | 1600 | 2000 | 2650 | ||||
Depth (mm) | 900 | ||||||||||
Net Weight (kg) | 370 | 510 | 725 | 990 | 1135 | 1550 | 2275 |
Nominal Ratings(kVA/kW) | 80kVA/kW | 100kVA/kW | 120kVA/kW | 160kVA/kW | 200kVA/kW | |
---|---|---|---|---|---|---|
Input | ||||||
Nominal input voltage(V) | 380/400/415 | |||||
Input voltage range without battery discharge (V) | 229~478 | |||||
Nominal input frequency(Hz) | 50/60 | |||||
Input frequency range(Hz) | 40-70 | |||||
Bypass voltage tolerance(%) | Upper limit: +10%, +15%, or +20% default: +15%;
Lower limit: -10%, -20%, -30% or -40% default: -20% |
|||||
Bypass frequency tolerance(%) | +/- 10% or +/- 20%, default: +/-10% | |||||
Input power factor(kW/kVA) | 0.99 | |||||
Current THD at full linear load(THDi%) | 3% | |||||
Output | ||||||
Nominal output voltage (V) | 380/400/415 | |||||
Nominal output frequency (Hz) | 50/60 | |||||
Nominal active power (kW) | PF=1 | |||||
THDv with 100% linear load (%) | 1% | |||||
Inverter overload capacity | 110% for 60 min; 125% 10min; 150% for 1 min | |||||
Dimensions and weight | ||||||
Dimensions (W x D x H) mm | 600 x 1000 x 2000 | |||||
Weight(Net weight) | 385 430 430 475 520 |
Rated Power (In kVA/kW)* | 18 | 36 | 54 | 72 | 90 | |
---|---|---|---|---|---|---|
Input | ||||||
Rated input voltage | 380/400/415Vac, 3-phase and 4 -wire | |||||
Input voltage range | 305~477V ; 304-228 V for ( o/p derated below 80%) | |||||
Rated operating frequency | 50/60Hz | |||||
Input frequency range | 40-70Hz | |||||
Input power factor | =0.99 at full load, >0.98 at half load | |||||
THDi* | Linear full load 3% (battery float charge); Non-liner full load 5% (battery float charge) | |||||
Input power walk-in duration | 20s | |||||
Output | ||||||
Inverter output voltage | 380/400/415Vac, 3-phase and 4-wire | |||||
Nominal output frequency | 50/60 (settable) | |||||
Inverter overload capacity | 1 hour for 110%; 10 mins for 125%; 1 min for 150%; 200ms for >150% | |||||
Voltage Stability | ±1% (balanced) | |||||
Total harmonic voltage distortion | 2% (linear load); 4% (non-linear load) | |||||
Slew rate | 0.6Hz/sec | |||||
Dimensions and weight | ||||||
Dimensions (W x D x H) (mm) | 600 x 1100 x 2000 | |||||
Weight(kg) | 228 256 284 321 340 |
MODEL | SPECIFICATION | EXi 600 VA | LXi 600 VA | CX 600 VA | 1000 VA LB |
---|---|---|---|---|---|
CAPACITY | VA/W | 600 VA/360 Watt. | 600 VA/360 Watt. | 600 VA/360 Watt. | 1000 VA/600 Watt. |
Input | Voltage | 220/230 VAC | |||
Voltage Range | 140-300 VAC | ||||
Frequency Range | 50 Hz | ||||
OUTPUT | AC Voltage Regulation (Batt. Mode) | ±10% | |||
Frequency Range (Batt. Mode) | 50 Hz ±1 Hz | ||||
Transfer Time | Typical 2-6 ms | ||||
Waveform (Batt. Mode) | Simulated Sine Wave | ||||
Overload | 110% +/-10% Shutdown after 5 mins | ||||
BATTERY | Battery Type & Number | 12 V/9Ah x 1 | 12 V/7 Ah x 2 | 12 V/7 Ah x 1 | 12VDC |
Floating Charge Voltage | 13.7 VDC ± 2% | ||||
Overcharge Protection | 14.5VDC ± 2% | ||||
Maximum Charge Current | 20 A | ||||
Typical Recharge Time | 6-8 hours up to 90% capacity | ||||
TRANSFER TIME | Minimum line break for transfer to battery | Typical 4-8 msec | |||
PHYSICAL | Dimension, D X W X H (mm) | 282 x 101 x 142 | 353 X 150 x 162 | 279 X 101 X142 | 350 x 146 x 160 |